(25 pts) Estimate how much collector area and storage capacity would be required for an active solar hot-water system designed to supply the total needs for two four-person families, one living in Manchester, New Hampshire, where the latitude is 44+o north and the other in Albuquerque, New Mexico, at 35+o North. The heat capacity of water is about 4200 J/kgoC and the hot water supply temperature in both houses is 60oC (140oF). State and justify all additional assumptions made.

Respuesta :

Answer:

The required  total area is 1.48 m²

Explanation:

Given that,

Latitude = 44+° N

New Mexico,

Latitude= 35+° N

Heat capacity = 4200 J/Kg°C

Temperature = 60°C

Let us assume the input temperature 22°C

Estimate volume of water 100 ltr for 4 person.

We need to calculate the heat

Using formula of heat

[tex]H=mc_{p}\Delta T[/tex]

[tex]H=mc_{p}(T_{f}-T_{i})[/tex]

Put the value into the formula

[tex]H=100\times4200\times(60-22)[/tex]

[tex]H=15960\ KJ[/tex]...(I)

Let solar radiation for 6 hours/day.

We need to calculate the total energy per unit area

Using formula of energy

[tex]E=1000\times6\times3600\ J/m^2[/tex]

[tex]E=21600\ KJ/m^2[/tex]

Let the efficiency of collector is 50 %

Then,  the total energy per unit area will be

[tex]E=21600\times\dfrac{50}{100}[/tex]

[tex]E=10800\ KJ/m^2[/tex]....(II)

We need to calculate the required total area

Using equation (I) and (II)

[tex]A=\dfrac{H}{E}[/tex]

Where, H = heat

E = total energy

Put the value into the formula

[tex]A=\dfrac{15960}{10800}[/tex]

[tex]A=1.48\ m^2[/tex]